head_banner

480g/L Glyphosate-isopropylammonium Salt SL

480g/L Glyphosate-isopropylammonium Salt SL

 

1.Proportion of Raw material

Composition

Kg/KL

Glyphosate TC(95%)

374.5

Isopropylamine(70%)

205

Adjuvant S305

150

Water

485.5

Defoamer

appropriate amount

Colourant

appropriate amount

   

PH:4.7-5.0

Density:1.17

2. Manufacturing Process

① Charging: First put the water into the reactor, start the mixing, after putting in the glyphosate TC, slowly add isopropylamine to start the reaction, control the dropping speed, not too fast, make the heating keep the reaction temperature in the reactor at 50-60℃, and heat the reaction for 1 hour after dropping isopropylamine;

③ Test: take a small sample to observe that the preparation is clear and transparent, and then measure the indicators. Follow up operations can be carried out after the indicators are qualified。

3. Attention:

l  Colourant and defoamer should be added according to the guidance dosage. Excessive use will affect the viscosity or transparency of the preparation. Please pay attention to the experimental verification.

480g/L Glyphosate-isopropylammonium Salt SL